XI'AN YUMU ELECTRONICS TECHNOLOGY CO.,LTD
XI'AN YUMU ELECTRONICS TECHNOLOGY CO.,LTD
Home> NEWS> How to Test Military Metal Relay Performance - Military Metal Relays

How to Test Military Metal Relay Performance - Military Metal Relays

2025,12,08

How to Test Military Metal Relay Performance: A Practical Guide for B2B Procurement

For procurement managers, quality engineers, and maintenance teams, verifying the performance of a Military Metal Sealing Relay is a critical step in ensuring system reliability and supply chain integrity. Whether you're conducting incoming inspection, qualifying a new supplier, or troubleshooting a field issue, a systematic testing approach is essential. This comprehensive guide outlines practical methods to validate the key performance parameters of military relays, providing you with the knowledge to make data-driven decisions and ensure components meet the rigorous demands of Aircraft Engine controls, defense systems, and industrial applications.

JRC-29M J65B.RG0555.027.03 Metal Relay

Essential Test Equipment and Preparation

Before beginning, gather the appropriate tools to ensure accurate and repeatable measurements. A basic test setup should include:

  • Digital Multimeter (DMM): A high-precision model capable of measuring low resistance (milliohms) and low current (milliamps).
  • DC Power Supply: A regulated, adjustable supply capable of providing the relay's rated coil voltage and the test current for contact loading.
  • Load Bank/Resistive Load: To apply a rated or derated load to the contacts during operational tests.
  • Micro-ohmmeter (Optional but Recommended): For the most accurate contact resistance measurement using a 4-wire Kelvin method.
  • Insulation Resistance Tester (Megohmmeter): For verifying dielectric integrity.
  • Test Fixture: A secure socket or fixture to hold the relay firmly without stressing the pins or casing, crucial for consistent testing of PCB Board Relay and plug-in types.

Pre-Test Protocol: Safety and Baseline

Always handle Military Metal Relays with ESD precautions. Before applying any tests, visually inspect the unit for physical damage, cracked seals, or corroded terminals. Record the relay's part number, batch code, and any initial observations. This baseline is critical for comparison with other units or future retests.

Step-by-Step Performance Test Procedure

Follow this sequential testing methodology to thoroughly evaluate a Military Relay's performance. These steps mirror the key checks performed in our own incoming inspection protocols.

Step 1: Coil Circuit Verification

  1. Coil Resistance Measurement: Using your DMM, measure the DC resistance across the coil terminals. Compare this value to the specified range in the datasheet (e.g., 160Ω ±10% for a 28VDC coil). A reading outside tolerance indicates a shorted, open, or out-of-spec coil winding.
  2. Operate/Release Voltage Test: Connect the coil to your adjustable power supply. Slowly increase the voltage from zero until the relay audibly clicks and the contacts change state—this is the pull-in voltage. Note it should be ≤ 75% of the rated voltage typically. Then, slowly decrease the voltage until the relay releases (drop-out voltage). This is especially important for sensitive Polarized Relay and Latching Relay variants.

Step 2: Contact System Analysis

  1. Contact Resistance (Critical Test): This is the most telling parameter for contact health. Using a micro-ohmmeter or the 4-wire function on a high-end DMM, measure the resistance across the closed (NO or NC) contacts. Apply a low test current (<100mA) to avoid skewing results. For a new, high-quality Military Metal Sealing Relay, expect values under 100 milliohms. Record this value as a baseline for future predictive maintenance.
  2. Contact Functionality & Bounce: Using the DMM in continuity mode, cycle the relay multiple times. Observe the switch action. Listen and watch for excessive contact bounce (indicated by a chattering sound or flickering meter). While specialized equipment measures bounce time, a stable, single switch action is a good qualitative indicator.
Military Metal Relay JZC-1M 27VDC

Step 3: Dielectric Strength & Isolation Checks

  1. Insulation Resistance: Using a megohmmeter, apply 500VDC between electrically isolated circuits (e.g., between open contact sets, and between all contacts and the metal case/coil). A reading > 1,000 MΩ is standard for military-grade components. This test is vital for safety in high-voltage or sensitive applications like those interfacing with a High quality Aviation Engine sensor suite.
  2. Dielectric Withstanding Voltage (HIPOT - Caution): This high-potential test requires specialized, safe equipment. It applies a high AC voltage (e.g., 1,000 Vrms) between isolated circuits to verify no breakdown occurs. This test is typically destructive if failed and is usually performed on a sample basis rather than 100% inspection.

Step 4: Basic Functional Life Test (Sample or Suspicion-Based)

If you suspect an issue or are performing batch qualification, a simplified life test can be revealing.

  • Set up the relay to switch a derated load (e.g., 50% of rated current) at a slow cycle rate (e.g., 1 Hz).
  • Run it for several thousand cycles.
  • Periodically stop and re-measure contact resistance. A significant increase indicates contact wear or degradation.
  • This principle applies to testing an Automotive Relay for a fleet vehicle or an Industrial Power Relay for a production line.

Industry Trends: Advanced Diagnostics and Smart Testing

The field of component testing is evolving from basic pass/fail to predictive analytics:

  • Automated Test Equipment (ATE) Integration: High-volume manufacturers and sophisticated users are adopting ATE systems that can perform all standard tests in seconds, logging data for SPC (Statistical Process Control) and traceability.
  • Dynamic Parameter Analysis: Advanced systems now analyze the shape of the operate/release transient or contact bounce waveform, which can predict mechanical wear or spring fatigue before failure.
  • Condition-Based Monitoring (CBM) Feeds: In deployed systems, relays are increasingly part of networks where parameters like coil current or contact voltage drop can be monitored in real-time, shifting testing from scheduled intervals to an ongoing process.
2 JRW-111MA TO-5 TP 411D Teledyne

5 Key Verification Requirements for Russian Technical Audits

When Russian procurement or quality teams audit a supplier's testing capability, they focus on:

  1. Calibration Traceability to GOST R: All test equipment must have valid calibration certificates issued by a lab accredited to the Russian metrology system (Rosstandart), with a clear chain of traceability.
  2. Test Method Alignment with GOST Standards: The step-by-step procedure must align with GOST test methods (e.g., GOST R 52931 for vibration, GOST 28205 for climate) in addition to any MIL-STD methods used.
  3. Witnessed Testing of Production Batches: The right to send an inspector to witness the conformance testing of their specific order lot is a common contractual requirement for defense and state contracts.
  4. Raw Data Access and Long-Term Archiving: Expectation of full access to raw test data, not just summary pass/fail certificates. They also require proof that this data is archived for the product's declared lifecycle (often 10+ years).
  5. Failure Analysis (FA) Capability: If a sample fails, the supplier must demonstrate competent FA capability—including decapsulation (for non-hermetic types), microscopic inspection, and material analysis—to determine the root cause, not just replace the unit.

Interpreting Results and Common Failure Modes

Red Flags in Test Data

  • Rising Contact Resistance: The primary indicator of contact surface contamination, wear, or softening.
  • High or Erratic Operate Voltage: Can indicate mechanical binding, weak magnetic field (coil issue), or contamination in the armature gap.
  • Low Insulation Resistance: Suggests moisture ingress (seal failure), internal contamination, or degraded insulation materials.
  • Excessive Contact Bounce: Can cause arcing, weld failures, and logic errors in digital systems. This is a critical parameter for PCB Signal Relays in communication equipment.

YM's Testing Philosophy: From Incoming Material to Final Shipment

At YM, performance testing is embedded at every stage. Our 45,000 sq.m. facility includes a dedicated validation center where we not only test finished relays but also the raw materials that go into them. Every batch of Military Metal Relays undergoes 100% final functional testing, and sample batches from every production run are subjected to full environmental stress screening. Our R&D team has developed proprietary automated optical inspection (AOI) algorithms that can detect sub-micron anomalies in contact alignment—a preemptive test that prevents latent failures and is a testament to our investment in predictive quality rather than just inspection.

default name

Frequently Asked Questions (FAQ)

Q1: Can I perform a basic hermeticity (seal) test without a helium mass spectrometer?

A: For a definitive pass/fail per MIL-STD-883, you need the proper equipment. However, a strong indicative test is the Gross Leak Bubble Test. Submerge the pressurized relay in a fluid (like fluorocarbon) and look for a stream of bubbles. While not a substitute for fine leak testing, it can identify obvious seal failures. For qualified components like our hermetically sealed relays, reliance on the manufacturer's certified test report is standard practice.

Q2: How do I test a Latching relay differently from a standard relay?

A: The key difference is testing the pulse operation and bistable state. You must: 1. Apply a short, rated-voltage pulse of correct polarity to the "Set" coil and verify it latches. 2. Remove power completely and verify it holds state. 3. Apply a similar pulse to the "Reset" coil (or reverse polarity for single-coil types) and verify it releases. Testing coil resistance and contact parameters then proceeds as normal. This logic is also relevant for certain Solid State Relay for Drone control circuits.

Q3: What is a reasonable "Acceptable Quality Level" (AQL) for sampling incoming military relays?

A: For critical applications, an AQL of 0.65% or even 0.1% for major defects is common, often following MIL-STD-105/1916 sampling plans. The sample size and accept/reject criteria should be defined in your procurement contract. For less critical applications or after a supplier is qualified, AQL 1.0% or 1.5% might be used. The key is consistency and agreement with the supplier.

Q4: Are these test methods applicable to New Energy Relay applications, like EV charging station contactors?

A: The core principles (contact resistance, coil check, insulation) are universal. However, EV contactors have unique additional tests: High-Potential DC Testing (for 400V/800V systems), Arc Quenching Performance under high DC current, and Lifetime Cycle Testing under specific load profiles. While the basic verification steps in this guide are a good start, full qualification for New Energy requires application-specific test regimens that supplement military-standard tests.

Standards Governing Performance Test Methods

Reliable testing is grounded in standardized methods. Key references include:

  • MIL-STD-202: The foundational standard for test methods on electronic components, detailing procedures for electrical, environmental, and physical tests.
  • MIL-PRF-6106: The performance specification that defines what parameters must be tested and their pass/fail limits for military relays.
  • IEC 61810-1 & -2: International standards covering test and measurement procedures for electromechanical elementary relays.
  • GOST R 50030.5.1 & GOST 28205: Key Russian standards specifying test methods and requirements for low-voltage equipment and climatic resistance, respectively.
  • ISO/IEC 17025: The international standard for testing and calibration laboratories. YM's in-house labs are accredited to this standard, ensuring the competence and impartiality of our testing data.
JRW-270MA (2)

References and Technical Sources

1. Department of Defense. (2020). *MIL-STD-202H, Test Method Standard for Electronic and Electrical Component Parts, Method 307: Contact Resistance*. DLA.
2. International Electrotechnical Commission. (2022). *IEC 61810-1: Electromechanical elementary relays - Part 1: General and safety requirements*.

 

 

 

 

Contact Us

Author:

Ms. Linda Deng

Phone/WhatsApp:

+86 13759943660

Popular Products
You may also like
Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be between 20-8000 characters

Contact Us

Author:

Ms. Linda Deng

Phone/WhatsApp:

+86 13759943660

Popular Products

Contact

Send Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send