Product Attributes

Model No.JSB-82M

BrandYM

OutputDc

Relay TypeTelecom

Ambient Temperature-55℃~125℃

Relativehumidity98% at 40℃

Cyclone1kPa

Dither20g,10Hz~2000Hz

Random Vibration0.2g²/Hz,169.1m/s²

Workingvoltage(28.5±10%)Vd.c.

DielectricwithstandvoltageNormal atmospheric pressure:500Vr.m.s., 50Hz Under low pressure: 250Vr.m. s .,50 Hz

Input Currenton≤70mA

Insulationresistance≥ 1 0 0 0 M Ω

Contact ResistanceInitial value ≤50m Life test after ≤100mQ

TightnessLeakage rate ≤10Pa ·cm³/s

Packaging & Delivery
Military Aviation DC Relay

JSB-82M Military Aviation Sealed Hybrid Delay Relay - Direct Replacement for USA LOGITEK MOD Series

Product Overview

The JSB-82M is an advanced Military Metal Sealing Relay featuring course-programmable hybrid delay technology for complex aerospace sequencing applications. This sophisticated Aviation DC Relay serves as a direct replacement for USA-designed LOGITEK MOD series components, offering enhanced programmability and reliability in critical military systems. As a precision Military Electromagnetic Relay with integrated hybrid timing circuits, it combines electromagnetic switching robustness with solid-state timing accuracy for mission-critical delay functions. Manufactured by YM with 18+ years of specialized expertise, this Solid State Relay hybrid solution provides programmable delay capabilities with multiple timing modes, making it ideal for replacing aging LOGITEK components in legacy aerospace systems.

Product Images

JSB-82M sealed hybrid delay relay overview and compatibility JSB-82M technical specifications and programming options JSB-82M dimensional drawings and mounting details JSB-82M hybrid circuit design and timing mode diagrams

Technical Specifications

  • Relay Type: Hybrid Programmable Delay (Electromagnetic + Solid-State)
  • Contact Configuration: DPDT (Double Pole Double Throw)
  • Rated Coil Voltage: 27VDC Standard
  • Contact Rating: 1A @ 28VDC Resistive Load
  • Coil Power Consumption: 0.3-0.43W
  • Delay Range: Programmable from 10ms to 999 seconds (16.65 minutes)
  • Timing Modes: On-delay, Off-delay, Interval, One-shot programmable
  • Delay Accuracy: ±1% of set value or ±20ms (whichever is greater)
  • Contact Resistance: Initial ≤50mΩ; After life test ≤200mΩ
  • Operate/Release Time: ≤4ms each (excluding programmed delay)
  • Dielectric Strength: 500Vr.m.s. @ normal pressure; 250Vr.m.s. @ low pressure
  • Insulation Resistance: >500MΩ normal; >50MΩ post high-level life test
  • Weight: <3g
  • Sealing Performance: Hermetically sealed; Leakage rate ≤10⁻³ Pa·cm³/s
  • Programming Method: Course programming via external resistor or factory pre-set
  • Operating Temperature: -65°C to +125°C
  • Direct Replacement For: USA LOGITEK MOD series hybrid delay relays

Key Features & Advantages

  1. Course-Programmable Hybrid Design: Combines electromagnetic contact reliability with precise solid-state timing circuits for optimal performance in harsh environments.
  2. Multiple Timing Modes: Supports on-delay, off-delay, interval timing, and one-shot operation for versatile application scenarios.
  3. Direct LOGITEK Compatibility: Form-fit-function replacement for USA-designed LOGITEK MOD series, including programming interface compatibility.
  4. Enhanced Timing Flexibility: Wide 10ms to 999-second delay range with four operational modes exceeds original LOGITEK capabilities.
  5. Temperature-Stable Performance: Advanced timing circuits maintain accuracy across full military temperature range (-65°C to +125°C).
  6. Optimized PCB Board Relay Integration: Compact design with programming pins arranged for easy integration into existing LOGITEK-based systems.

Application Scenarios

This versatile Military Metal Relay is engineered for complex timing applications:

  • Aircraft System Sequencing: Engine start sequencing, landing gear operations, and avionics power-up delays
  • Weapon System Controls: Safe-arm delays, firing sequences, and deployment timing in military platforms
  • Test & Simulation Equipment: Timing functions for avionics testing, system verification, and training simulators
  • Emergency System Controls: Backup system activation delays, safety interlocks, and emergency procedure timing
  • Industrial Process Sequencing: Complex manufacturing processes requiring precise timing between operations
  • Legacy System Sustainment: Direct replacement in aging LOGITEK MOD based systems with enhanced functionality

Installation & Programming Steps

  1. System Analysis: Identify existing LOGITEK MOD model and timing requirements.
  2. Timing Mode Selection: Determine appropriate timing mode (on-delay, off-delay, interval, or one-shot).
  3. Delay Parameter Configuration: Calculate required delay times for each application.
  4. Programming Implementation: Configure via external resistor network or specify factory pre-programming.
  5. PCB Compatibility Verification: Confirm footprint and pin alignment matches LOGITEK MOD layout.
  6. Component Replacement: Carefully desolder existing LOGITEK relay using appropriate equipment.
  7. Programming Verification: Test timing functions before system integration if possible.
  8. System Integration Testing: Verify full functionality under actual operating conditions.
  9. Course Programming Sealed Hybrid Delay Relay  JSB-82M 
  10. Aviation Relay JSB 82M Sealed Hybrid Delay Model JSB 82M
  11. Military Sealed Hybrid Delay Relay JSB 82M for Military Use
  12. Aviation Relay JSB 82M replace of USA LOGITEK MOD Series
  13.  
  14. Metal Relay Designed for Aviation and Military Applications
  15. Aviation Relay with Military Grade Metal Design
  16. Military Aviation Relay for Drone,Aircraft Engine PCB Board 
  17. High quality Aviation relay for Engine,Train,Plane maintain

Procurement Value Proposition

  • Legacy System Support: Direct replacement for obsolete LOGITEK components extends service life of critical systems.
  • Enhanced Functionality: Multiple timing modes and wider delay range provide capabilities beyond original LOGITEK designs.
  • Reduced Qualification Time: Form-fit-function compatibility minimizes system requalification requirements.
  • Supply Chain Security: Reliable manufacturing source for components no longer available from original suppliers.
  • Cost-Effective Sustainment: Extends operational life of existing systems at fraction of complete system replacement cost.

Certifications & Compliance

  • CE and UL certified components and materials
  • Compliant with MIL-PRF-6106 Military Relay specifications
  • SGS-audited manufacturing processes and quality systems
  • RoHS compliant materials and production methods
  • ISO 9001:2015 certified quality management system
  • Timing accuracy testing per relevant military and aerospace standards

Customization Options

While optimized as a LOGITEK replacement, YM offers comprehensive customization:

  • Custom delay ranges and timing characteristics matching specific LOGITEK variants
  • Alternative programming interfaces compatible with existing LOGITEK circuits
  • Modified contact configurations or current ratings for upgraded applications
  • Enhanced sealing for specific environmental requirements
  • Special timing accuracy calibration for critical military applications
  • Private labeling and LOGITEK-compatible documentation packages

Our expertise spans Automotive Relay, Industrial Power Relay, and PCB Signal Relay technologies, with specialized experience in hybrid timing relay design for legacy system support.

Quality Assurance Process

Every JSB-82M undergoes rigorous 8-stage quality verification:

  1. Incoming material certification for hybrid circuit components
  2. Precision assembly with automated optical inspection of timing circuits
  3. Timing mode functional testing across all four operational modes
  4. Delay accuracy calibration at multiple set points across temperature range
  5. Hermetic sealing verification with leak rate testing
  6. Electrical performance testing under simulated operating conditions
  7. LOGITEK MOD compatibility verification including programming interface
  8. Final inspection with timing function validation and lot traceability

Frequently Asked Questions

Q1: What does "course-programmable" mean for this relay?

A1: Course-programmable refers to the ability to set delay times in coarse increments (typically via external resistor values) rather than fine digital programming, maintaining compatibility with original LOGITEK MOD series programming methods while offering improved accuracy.

Q2: How does the JSB-82M improve upon original LOGITEK MOD relays?

A2: While maintaining full compatibility, the JSB-82M offers enhanced timing accuracy (±1% vs typical ±5-10%), wider temperature range operation, four timing modes versus typically one or two, and modern manufacturing with full traceability.

Q3: What timing modes are available and how are they selected?

A3: Four modes: On-delay (delay after energization), Off-delay (delay after de-energization), Interval (fixed duration output), and One-shot (single pulse output). Mode selection is via factory configuration or external circuit modification per application requirements.

Q4: Can existing LOGITEK programming circuits be used without modification?

A4: Yes, the JSB-82M maintains resistor-based programming compatibility with LOGITEK MOD series. For applications requiring different timing ranges, simple resistor value adjustments may be needed, with guidance provided in our technical documentation.

Q5: Are samples available for LOGITEK replacement evaluation?

A5: Yes, we provide up to 3 free samples programmed to match specific LOGITEK MOD configurations for qualified B2B customers. Please provide original LOGITEK part number and timing requirements with your request.

Q6: What lead time can be expected for production quantities?

A6: Standard LOGITEK-compatible configurations: 3-4 weeks. Custom programming for specific MOD variants: 4-5 weeks. Bulk orders for legacy system sustainment programs receive priority scheduling.

Hot Products
Home> PRODUCTS> Aviation DC Relay> Aviation Metal Power Relay> Course Programming Sealed Hybrid Delay Relay JSB-82M

Contact

Send Inquiry

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send